SNo |
IS Number |
Title |
Technical Committee |
1 |
IS 694 : 2010 |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 1 100 V (Fourth Revision) |
ETD 9 |
2 |
IS 1554 : Part 1 : 1988 |
Specification for PVC insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1 100 V (Third Revision) |
ETD 9 |
3 |
IS 1554 : Part 2 : 1988 |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
ETD 9 |
4 |
IS 2189 : 2008 |
Selection, installation and maintenance of automatic fire detection and alarm system code of practice (Fourth Revision) |
CED 22 |
5 |
IS 3614 : 2021 |
Fire Doors and Doorsets - Specification (first revision) |
CED 36 |
6 |
IS 5819 : 1970 |
Recommended short - Circuit ratings of high voltage PVC cables |
ETD 9 |
7 |
IS 7098 : Part 1 : 1988 |
Specification for crosslinked polyethylene insulated PVC sheathed cables: Part 1 for working voltages up to and including 1 100 volts (First Revision) |
ETD 9 |
8 |
IS 7098 : Part 2 : 2011 |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
ETD 9 |
9 |
IS 7098 : Part 3 : 1993 |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
ETD 9 |
10 |
IS 8757 : 2021 |
Glossary of Terms Associated With Fire Safety (Second Revision) |
CED 36 |
11 |
IS 9968 : Part 1 : 1988 |
Specification for elastomer insulated cables: Part 1 for working voltages up to and including 1 100 volts (First Revision) |
ETD 9 |
12 |
IS 9968 : Part 2 : 2002 |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
ETD 9 |
13 |
IS 10810 : Part 53 : 1984 |
Methods of test for cables: Part 53 flammability test |
ETD 9 |
14 |
IS 10810 : Part 62 : 1993 |
Method of tests for cables: Part 62 flame retardance test for bunched cables |
ETD 9 |
15 |
IS 12458 : 2019 |
Fire Resistance of Through Penetration Firestops - Method of Test ( First Revision ) |
CED 36 |
16 |
IS 15519 : 2020 |
Water Mist Fire Protection Systems - System Design, Installation and Commissioning - Code of Practice ( First Revision ) |
CED 22 |
17 |
IS 16246 : 2015 |
Elastomer insulated cables with limited circuit integrity when affected by fire - Specification |
ETD 9 |
18 |
IS 17048 : 2018 |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
ETD 9 |
19 |
IS 17505 : Part 1 : 2021 |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1 100 V a.c. and 1 500 V d.c. |
ETD 9 |
20 |
IS/ISO 834 : Part 4 : 2000 |
Fire-Resistance Tests Elements of Building Construction Part 4 Specific Requirements for Load Bearing Vertical Separating Elements |
CED 36 |
21 |
IS/ISO 7240 : Part 5 : 2012 |
Fire Detection and Alarm Systems Part 5 Point-Type Heat Detectors |
CED 22 |
22 |
IS/ISO 7240 : Part 7 : 2011 |
Fire detection and alarm systems: Part 7 point - Type smoke detectors using scattered light, transmitted light or ionization |
CED 22 |
23 |
IS/IEC 62222 : 2012 |
Fire performance of communication cables installed in buildings |
LITD 6 |
24 |
IS/ISO 10993 : Part 7 : 2018 |
Biological evaluation of medical devices Part 7 Ethylene oxide sterilization residuals |
MHD 19 |
25 |
IS 732 : 2019 |
Code of practice for electrical wiring installations (Fourth Revision) |
ETD 20 |
26 |
SP 30 : 2023 |
NATIONAL ELECTRICAL CODE OF INDIA 2023 (Second Revision) |
ETD 20 |
27 |
IS/IEC 61537 : 2006 |
Cable Management - Cable Tray System and Cable Ladder System |
ETD 14 |