BUREAU OF INDIAN STANDARDS
Programme of Work
ETD6 : Electrical Insulators And Accessories
- Scope : To prepare standards regarding insulated bushing, insulators for overhead lines, insulators for sub-stations and jointing accessories which are integral parts of insulators
-
Liaison :IEC TC 36 - Insulators - Participating (P)
IEC TC 36 / SC 36A - Insulated bushings - Participating (P)
IS 10136 : 1982 Reviewed In : 2021 |
Code of practice for selection of disc insulator fittings for highest system voltages of 72.5 kV and above
|
July, 2021
|
-
|
Indigenous
|
|
IS 10314 : 1982 Reviewed In : 2021 |
Dimensions for ceramic bushings for terminals
|
January, 2021
|
-
|
Modified/Technically Equivalent
|
|
IS 12676 : 1989 Reviewed In : 2021 |
Oil impregnated paper insulated condenser bushings - Dimensions and requirements
|
July, 2021
|
-
|
Indigenous
|
|
IS 13134 : 1992 Reviewed In : 2018 |
Guide for the selection of insulators in respect of polluted conditions
|
April, 2018
|
-
|
Modified/Technically Equivalent
|
|
IS 13305 : 1992 Reviewed In : 2018 |
Permissible limits of visual defects for insulating porcelains for electrical circuits
|
April, 2018
|
-
|
Modified/Technically Equivalent
|
|
IS 13312 : 1992 Reviewed In : 2018 |
Dimensions of porcelain oil filled transformer bushings (Rated 52 KV) for medium polluted atmospheres
|
April, 2018
|
-
|
Indigenous
|
|
IS 1441 : 1989 Reviewed In : 2019 |
Insulator stalks for telegraph and telephone lines - Specification (Second Revision)
|
-
|
Indigenous
|
||
IS 1445 : 1977 Reviewed In : 2019 |
Specification for porcelain insulators for overhead power lines with a nominal voltage up to and including 1 000 V (Second Revision)
|
5
|
Indigenous
|
||
IS 15137 : 2002 Reviewed In : 2024 |
Metal connecting lugs for porcelain transformer bushings - Specification
|
August, 2024
|
-
|
Indigenous
|
|
IS 16683 (Part 1) : 2018 IEC TS 60815-1 : 2008 Reviewed In : 2024 |
Selection and Dimensioning of High-Voltage Insulators Intended for Use in Polluted Conditions Part 1 Definitions, Information and General Principles
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16683 (Part 2) : 2018 IEC TS 60815-2 : 2008 Reviewed In : 2024 |
Selection and Dimensioning of High-Voltage Insulators Intended for Use in Polluted Conditions Part 2 Ceramic and Glass Insulators for a.c. Systems
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16683 (Part 3) : 2018 IEC/TS 60815-3 : 2008 Reviewed In : 2024 |
Selection and dimensioning of high - Voltage insulators intended for use in polluted conditions: Part 3 polymer insulators for a.c. systems
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16683 (Part 4) : 2021 60815-4 |
High-Voltage Insulators Intended for use in Polluted Conditions - Selection and Dimensioning Part 4 Insulators for d.c. Systems
|
-
|
Identical under dual numbering
|
||
IS 16684 : 2018 IEC 62217 : 2012 Reviewed In : 2024 |
Polymeric HV Insulators for Indoor and Outdoor Use-General Definitions, Test Methods and Acceptance Criteria
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16685 : 2018 IEC 62223 : 2009 Reviewed In : 2024 |
Insulators - Glossary of terms and definitions
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16686 : 2018 IEC TR 62662 : 2010 Reviewed In : 2024 |
Guidance for Production, Testing and Diagnostics of Polymer Insulators with Respect to Brittle Fracture of Core Materials
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16687 : 2018 IEC TR 62730 : 2012 Reviewed In : 2024 |
HV Polymeric Insulators for Indoor and Outdoor Use Tracking and Erosion Testing by Wheel Test and 5000 h Test
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 16784 : 2018 IEC 61109:2008 Reviewed In : 2024 |
Insulators for Overhead Lines - Composite Suspension and Tension Insulators for a.c. Systems with a Nominal Voltage Greater Than 1 000 V - Definitions, Test Methods and Acceptance Criteria
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 2486 (Part 1) : 1993 Reviewed In : 2018 |
Metal fittings of insulators for overhead power lines with nominal voltage greater than 1 000 V - Specification: Part 1 general requirements and tests (Second Revision)
|
April, 2018
|
-
|
Indigenous
|
|
IS 2486 (Part 2) : 1989 Reviewed In : 2019 |
Insulator fittings for overhead power lines with nominal voltage greater than 1 000 V - Specification: Part 2 dimensional requirements (Second Revision)
|
-
|
Indigenous
|
||
IS 2486 (Part 3) : 1974 Reviewed In : 2021 |
Specification for insulator fittings for overhead power lines with a nominal voltage greater than 1 000 volts: Part 3 locking devices
|
July, 2021
|
-
|
Modified/Technically Equivalent
|
|
IS 2486 (Part 4) : 1981 61372-2 Reviewed In : 2021 |
Specification for insulator fittings for overhead power lines with a nominal voltage greater than 1 000 V: Part iv tests for locking devices
|
July, 2021
|
-
|
Modified/Technically Equivalent
|
|
IS 283 : 1976 Reviewed In : 2021 |
Specification for porcelain insulators for telegraph and telephone lines (Third Revision)
|
July, 2021
|
4
|
Indigenous
|
|
IS 3347 (Part 1/Sec 1) : 1979 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part 1 up to and including 1 Kv: Sec 1 porcelain parts (First Revision)
|
1
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 1/Sec 2) : 1979 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part i up to and including 1 kV: Sec 2 metal parts (First Revision)
|
3
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 2/Sec 1) : 1979 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part ii 3.6 kV bushings: Sec 1 porcelain parts (First Revision)
|
1
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 2/Sec 2) : 1979 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part ii 3.6 kV bushings: Sec 2 metal parts (First Revision)
|
3
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 3/Sec 1) : 1988 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in 1 lightly polluted atmospheres: Part 3 17.5 kV bushings: Sec 1 porcelain parts (Second Revision)
|
-
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 3/Sec 2) : 1982 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part iii 12 and 17.5 kV bushings: Sec 2 metal parts (First Revision)
|
2
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 4/Sec 1) : 1988 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in lightly polluted atmospheres: Part 4 24 kv bushings: Sec 1 porcelain parts (Second Revision)
|
1
|
Indigenous
|
||
IS 3347 (Part 4/Sec 2) : 1982 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part 4 24 kV bushings: Sec 2 metal parts (First Revision)
|
3
|
Modified/Technically Equivalent
|
||
IS 3347 (Part 5/Sec 1) : 1979 Reviewed In : 2019 |
Dimension for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part 5 36 kV bushings: Sec 1 porcelain parts (Second Revision)
|
April, 2019
|
1
|
Modified/Technically Equivalent
|
|
IS 3347 (Part 5/Sec 2) : 1979 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in normal and lightly polluted atmospheres: Part 5 36 kV bushings: Sec 2 metal parts (First Revision)
|
2
|
Indigenous
|
||
IS 3347 (Part 8/Sec 1) : 1988 Reviewed In : 2019 |
Dimensions for porcelain transformer bushings for use in lightly polluted atmospheres: Part 8 52 kV bushings: Sec 1 porcelain part
|
April, 2019
|
-
|
Modified/Technically Equivalent
|
|
IS 3347 (Part 8/Sec 2) : 1992 Reviewed In : 2019 |
Dtmensions for porcelain transformer bushings for use in lightly polluted atmospheres: Part 8 52 kV bushings: Sec 2 metal parts
|
April, 2019
|
-
|
Indigenous
|
|
IS 4257 (Part 1) : 1981 Reviewed In : 2019 |
Dimensions for clamping arrangements for porcelain transformer bushings: Part 1 for 12 kV to 52 kV bushings (First Revision)
|
1
|
Modified/Technically Equivalent
|
||
IS 4257 (Part 2) : 1986 Reviewed In : 2019 |
Dimensions for clamping arrangements for porcelain transformer bushings: Part 2 for 72.5 kV and 123 kV bushings
|
-
|
Modified/Technically Equivalent
|
||
IS 4318 : 1993 Reviewed In : 2018 |
Solid core porcelain insulators for overhead traction lines - Specification (First Revision)
|
April, 2018
|
-
|
Indigenous
|
|
IS 5300 : 1969 Reviewed In : 2019 |
Specification for porcelain guy strain insulators
|
1
|
Modified/Technically Equivalent
|
||
IS 5350 (Part 1) : 1970 Reviewed In : 2019 |
Dimensions of indoor and outdoor porcelain post insulators and post insulator units for systems with nominal voltages greater than 1000 V: Part 1 indoor post insulators
|
2
|
Indigenous
|
||
IS 5350 (Part 2) : 1973 Reviewed In : 2019 |
Dimensions of indoor and outdoor porcelain post insulators and post insulator units for systems with nominal voltage greater than 1000 V: Part 2 outdoor cylindrical post insulators (First Revision)
|
-
|
Modified/Technically Equivalent
|
||
IS 5350 (Part 3) : 1971 Reviewed In : 2019 |
Dimensions of indoor and outdoor porcelain post insulators and post insulator units for systems with nominal voltages greater than 1000 V: Part 3 outdoor pedestal post insulators
|
3
|
Modified/Technically Equivalent
|
||
IS/IEC 60120 : 2020 IEC 60120:2020 |
Ball and socket couplings of string insulator units - Dimensions
|
-
|
Identical under single numbering
|
||
IS/IEC 60137 : 2017 IEC 60137: 2017 Reviewed In : 2024 |
Insulated Bushings for Alternating Voltages above 1 000 V
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC 60168 : 2000 IEC 60168 : 2001 Reviewed In : 2024 |
Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1 000 v
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC 60273 : 1990 IEC 60273 : 1990 |
Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1 000 v
|
-
|
Identical under single numbering
|
||
IS/IEC 60305 : 1995 |
Insulatore for Overhead Lines with a Nominal Voltage Above 1 000 V - Ceramic or Glass Insulator Units for a.c. Systems - Characteristics of Insulator Units of the Cap and Pin Type
|
-
|
Identical under single numbering
|
||
IS/IEC 60305 : 2021 IEC 60305:2021 |
Insulators for Overhead Lines with a Nominal Voltage Above 1 000 V - Ceramic or Glass Insulator Units for a.c. Systems - Characteristics of Insulator Units of the Cap and Pin Type ( First Revision )
|
-
|
Identical under single numbering
|
||
IS/IEC 60372 : 1984 Reviewed In : 2020 |
Locking devices for ball and socket couplings of string insulators units - Dimensions and tests
|
August, 2020
|
-
|
Identical under single numbering
|
|
IS/IEC 60372 : 2020 IEC 60372:2020 |
Locking devices for ball and socket couplings of string insulators units - Dimensions and tests (First Revision)
|
-
|
Identical under single numbering
|
||
IS/IEC 60383-1 : 1993 IEC 60383-1 : 1993 |
Insulators for Overhead Lines with a Nominal Voltage Above 1 000 V Part 1 Ceramic or Glass Insulator Units for a.c. Systems — Definitions, Test Methods and Acceptance Criteria
|
-
|
Identical under single numbering
|
||
IS/IEC 60383-1 : 2023 IEC 60383-1: 2023 |
Insulators for Overhead Lines with a Nominal Voltage above 1 000 V Part 1 Ceramic or Glass Insulator Units for a.c Systems - Definitions, Test Methods and Acceptance Criteria (First Revision)
|
-
|
Identical under single numbering
|
||
IS/IEC 60383-2 : 1993 IEC 60383-2 : 1993 |
Insulators for Overhead Lines with a Nominal Voltage Above 1 000 V Part 2 Insulator Strings and Insulator Sets for a.c. Systems — Definitions, Test Methods and Acceptance Criteria
|
-
|
Identical under single numbering
|
||
IS/IEC 60433 : 2021 IEC 60433:2021 |
Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic insulators for ac systems - Characteristics of insulator units of the long rod type
|
-
|
Identical under single numbering
|
||
IS/IEC 60471 : 2020 IEC 60471:2020 |
Clevis and Tongue Couplings of String Insulator Units � Dimensions (First Revision)
|
-
|
Identical under single numbering
|
||
IS/IEC/TR 60575 : 1977 IEC TR 60575:1977 |
Thermal-mechanical performance test and mechanical performance test on string insulator units
|
-
|
Identical under single numbering
|
||
IS/IEC 60720 : 1981 IEC 60720:1981 |
Line Post Insulators Characteristics
|
-
|
Identical under single numbering
|
||
IS/IEC 61211 : 2004 IEC 61211:2004 Reviewed In : 2024 |
Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1 000 V - Impulse puncture testing in air
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC/TS 61245 : 2015 IEC 61245 : 2015 Reviewed In : 2024 |
Artificial pollution tests on high - Voltage ceramic and glass insulators to be used on d.c. systems
|
August, 2024
|
1
|
Identical under single numbering
|
|
IS/IEC 61325 : 1995 IEC 61325:1995 |
Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic or glass insulator units for dc systems - Definitions test methods and acceptance criteria
|
-
|
Identical under single numbering
|
||
: 2023 IEC 61462: 2023 |
Composite Hollow Insulators - Pressurized and Unpressurized Insulators For Use in Electrical Equipment with a.c Rated Voltage Greater than 1 000 V and d.c Voltage Greater than 1 500 V - Definitions, Test Methods, Acceptance Criteria and Design Recommendations ( First Revision )
|
-
|
Identical under single numbering
|
||
IS/IEC 61462 : 2007 IEC 61462:2007 |
Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions test methods acceptance criteria and design recommendations
|
-
|
Identical under single numbering
|
||
IS/IEC/TS 61463 : 2016 61463-2016 Reviewed In : 2024 |
Bushings - Seismic qualification
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC/TS 62073 : 2016 IEC/TS 62073 : 2016 Reviewed In : 2024 |
Guidance on the Measurement of Hydrophobicity of Insulator Surfaces
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC 62155 : 2003 IEC 62155 : 2003 Reviewed In : 2024 |
Hollow Pressurized and Unpressurized Ceramic and Glass Insulators for Use in Electrical Equipment with Rated Voltages Greater Than 1 000 V
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC/TS 62371 : 2008 62371:2008 Reviewed In : 2024 |
Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS/IEC/TS 62896 : 2015 62896:2015 |
Hybrid insulators for ac and dc for high-voltage applications - Definitions test methods and acceptance criteria
|
-
|
Identical under single numbering
|
||
IS/IEC/IEEE 65700-19-3 : 2014 IEC/IEEE 65700-19-03 : 2014 Reviewed In : 2024 |
Bushing for DC Application
|
August, 2024
|
-
|
Identical under single numbering
|
|
IS 731 : 1971 Reviewed In : 2021 |
Specification for procelain insulators for overhead power lines with a nominal voltage greater than 1000 V (Second Revision)
|
June, 2021
|
7
|
Modified/Technically Equivalent
|
|
IS 7421 : 1988 Reviewed In : 2019 |
Specification for porcelain bushings for alternating voltages upto and including 1000 v (First Revision)
|
-
|
Indigenous
|
||
IS 7648 : 1975 Reviewed In : 2019 |
Specification for silicone compounds for application on high voltage porcelain insulators
|
-
|
Indigenous
|
||
IS 7935 : 1975 Reviewed In : 2021 |
Specification for insulator fittings for overhead power lines with a nominal voltage up to and including 1000 v
|
July, 2021
|
3
|
Indigenous
|
|
IS 8263 : 2018 IEC 60437 : 1997 |
Radio interference test on high - Voltage insulators (First Revision)
|
-
|
Identical under dual numbering
|
||
IS 8269 : 1976 Reviewed In : 2019 |
Methods for switching impulse tests on high voltage insulators
|
April, 2019
|
-
|
Modified/Technically Equivalent
|
|
IS 8603 : 2008 Reviewed In : 2024 |
Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres 12/17.5 kV, 24 kV and 36 kV (First Revision)
|
August, 2024
|
1
|
Indigenous
|
|
IS 8603 (Part 4) : 2003 Reviewed In : 2024 |
Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres: Part 4 52 kV bushings
|
August, 2024
|
-
|
Indigenous
|
|
IS 8704 : 2018 IEC 60507 : 2013 Reviewed In : 2024 |
Artificial pollution test on highVoltage ceramic and glass insulators to be used on a.c. systems (Second Revision)
|
August, 2024
|
-
|
Identical under dual numbering
|
|
IS 8765 : 1978 Reviewed In : 2019 |
Specification for ceramic insulating materials for electrical purposes
|
April, 2019
|
1
|
Modified/Technically Equivalent
|
|
IS 9431 : 2024 IEC 60660 :1999 |
Indoor Post Insulators of Organic Material for Systems with Nominal Voltages Greater Than 1000 V UP to and Including 300 kV - Specification (First Revision)
|
-
|
Identical under dual numbering
|
||
IS 9431 : 1979 Reviewed In : 2019 |
Specification for indoor post insulators of organic material for systems with nominal voltages greater than 1000 v up to and including 300 kV
|
April, 2019
|
-
|
Identical under dual numbering
|
|
IS/IEEE Std1523™ : 2018 IEEE 1523:2018 |
Guide for the Application Maintenance and Evaluation of Room Temperature Vulcanizing RTV Silicone Rubber Insulator Coatings
|
-
|
Identical under single numbering
|
No Records Found |
No Records Found |
No Records Found |
No Records Found |
No Records Found |
ETD 6 (25767)
Revision of: IS 8263:2018 |
Radio Interference Test on High-Voltage Insulators Second Revision |
|
IS 2099 : 1986 Reviewed In : 2018 |
Bushings for alternating voltages above 1 000 Volts |
|
IS 2544 : 1973 Reviewed In : 2016 |
Porcelain post insulators for systems with nominal voltage greater than 1000 V olts |
|
IS 3188 : 1980 Reviewed In : 2014 |
Characteristics Of String Insulator Units |
|
IS 3347 (Part 6/Sec 1) : 1977 Reviewed In : 1989 |
Dimensions for porcelain transformer bushings for use in lightly polluted atmospheres Part 6 72 5 kV bushings Sec 1 Porcelain parts |
|
IS 3347 (Part 6/Sec 2) : 1982 Reviewed In : 1988 |
Dimensions for porcelain transformer bushings for use in lightly polluted atmospheres Part 6 72 5 kV bushings Sec 2 Metal parts |
|
IS 3347 (Part 7/Sec 1) : 1977 Reviewed In : 1989 |
Dimensions for porcelain transformer bushings for use in lightly polluted atmospheres Part 7 123 kV bushings Sec 1 Porcelain parts |
|
IS 3347 (Part 7/Sec 2) : 1982 Reviewed In : 1988 |
Dimensions for porcelain transformer bushings for use in lightly polluted atmospheres Part 7 123 kV bushings Sec 2 Metal parts |
|
IS 5621 : 1980 Reviewed In : 2014 |
Hollow insulators for use in electrical equipment |
|
IS 8603 (Part 1) : 1977 Reviewed In : 2001 |
Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres Part 1 12 kV and 17 5 kV bushings Amalglamating in IS 8603 2008 |
|
IS 8603 (Part 2) : 1977 Reviewed In : 2001 |
Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres Part 2 24 kV buhsings Amalgamating in IS 8603 2008 |
|
IS 8603 (Part 3) : 1977 Reviewed In : 2001 |
Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres Part 3 36 kV bushings amalgamating in IS 8063 2008 |
IS 1441 : 1989 Reviewed In : 2019 |
Insulator stalks for telegraph and telephone lines - Specification Second Revision |
|
IS 1445 : 1977 Reviewed In : 2019 |
Specification for porcelain insulators for overhead power lines with a nominal voltage up to and including 1 000 V Second Revision |
|
IS 15137 : 2002 Reviewed In : 2024 |
Metal connecting lugs for porcelain transformer bushings - Specification |
|
IS 16684 : 2018 IEC 62217 : 2012 Reviewed In : 2024 |
Polymeric HV Insulators for Indoor and Outdoor Use-General Definitions Test Methods and Acceptance Criteria |
|
IS 2486 (Part 2) : 1989 Reviewed In : 2019 |
Insulator fittings for overhead power lines with nominal voltage greater than 1 000 V - Specification Part 2 dimensional requirements Second Revision |
|
IS 2486 (Part 3) : 1974 Reviewed In : 2021 |
Specification for insulator fittings for overhead power lines with a nominal voltage greater than 1 000 volts Part 3 locking devices |
|
IS 283 : 1976 Reviewed In : 2021 |
Specification for porcelain insulators for telegraph and telephone lines Third Revision |
|
IS 4318 : 1993 Reviewed In : 2018 |
Solid core porcelain insulators for overhead traction lines - Specification First Revision |
|
IS 5300 : 1969 Reviewed In : 2019 |
Specification for porcelain guy strain insulators |
|
IS/IEC 60137 : 2017 IEC 60137: 2017 Reviewed In : 2024 |
Insulated Bushings for Alternating Voltages above 1 000 V |
|
IS/IEC 60273 : 1990 IEC 60273 : 1990 |
Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1 000 v |
|
IS/IEC 60305 : 2021 IEC 60305:2021 |
Insulators for Overhead Lines with a Nominal Voltage Above 1 000 V - Ceramic or Glass Insulator Units for a c Systems - Characteristics of Insulator Units of the Cap and Pin Type First Revision |
|
IS/IEC 60372 : 2020 IEC 60372:2020 |
Locking devices for ball and socket couplings of string insulators units - Dimensions and tests First Revision |
|
IS/IEC 60383-1 : 2023 IEC 60383-1: 2023 |
Insulators for Overhead Lines with a Nominal Voltage above 1 000 V Part 1 Ceramic or Glass Insulator Units for a c Systems - Definitions Test Methods and Acceptance Criteria First Revision |
|
IS/IEC 60383-2 : 1993 IEC 60383-2 : 1993 |
Insulators for Overhead Lines with a Nominal Voltage Above 1 000 V Part 2 Insulator Strings and Insulator Sets for a c Systems Definitions Test Methods and Acceptance Criteria |
|
IS/IEC 60433 : 2021 IEC 60433:2021 |
Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic insulators for ac systems - Characteristics of insulator units of the long rod type |
|
IS/IEC 60720 : 1981 IEC 60720:1981 |
Line Post Insulators Characteristics |
|
: 2023 IEC 61462: 2023 |
Composite Hollow Insulators - Pressurized and Unpressurized Insulators For Use in Electrical Equipment with a c Rated Voltage Greater than 1 000 V and d c Voltage Greater than 1 500 V - Definitions Test Methods Acceptance Criteria and Design Recommendations First Revision |
|
IS/IEC 62155 : 2003 IEC 62155 : 2003 Reviewed In : 2024 |
Hollow Pressurized and Unpressurized Ceramic and Glass Insulators for Use in Electrical Equipment with Rated Voltages Greater Than 1 000 V |
|
IS/IEC/TS 62371 : 2008 62371:2008 Reviewed In : 2024 |
Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V |
|
IS/IEC/TS 62896 : 2015 62896:2015 |
Hybrid insulators for ac and dc for high-voltage applications - Definitions test methods and acceptance criteria |
|
IS/IEC/IEEE 65700-19-3 : 2014 IEC/IEEE 65700-19-03 : 2014 Reviewed In : 2024 |
Bushing for DC Application |
|
IS 731 : 1971 Reviewed In : 2021 |
Specification for procelain insulators for overhead power lines with a nominal voltage greater than 1000 V Second Revision |
|
IS 7421 : 1988 Reviewed In : 2019 |
Specification for porcelain bushings for alternating voltages upto and including 1000 v First Revision |
|
IS 7648 : 1975 Reviewed In : 2019 |
Specification for silicone compounds for application on high voltage porcelain insulators |
|
IS 7935 : 1975 Reviewed In : 2021 |
Specification for insulator fittings for overhead power lines with a nominal voltage up to and including 1000 v |
|
IS 8765 : 1978 Reviewed In : 2019 |
Specification for ceramic insulating materials for electrical purposes |
|
IS 9431 : 2024 IEC 60660 :1999 |
Indoor Post Insulators of Organic Material for Systems with Nominal Voltages Greater Than 1000 V UP to and Including 300 kV - Specification First Revision |