BUREAU OF INDIAN STANDARDS
Programme of Work
MHD2 : Orthopedic Instruments, Implants and Accessories
- Scope : To formulate Indian Standards for instruments used in orthopaedic surgery and orthopaedic implants (Excluding cardio-vascular and neuro-surgical implants) such as bone holding forceps, bone nail, bone cutting saws and bone drills, etc.
-
Liaison :ISO/TC 150/SC 1 - Materials - Participating (P)
ISO/TC 150/SC 5 - Osteosynthesis and spinal devices - Participating (P)
ISO/TC 150 - Implants for surgery - Participating (P)
ISO/TC 150/SC 4 - Bone and joint replacements - Participating (P)
ISO TC 150/SC 1/WG 3 - Ceramics
ISO TC 150/SC 1/WG 4 - Metals
ISO TC 150/SC 1/WG 5 - Plastics
ISO TC 150/SC 4/WG 1 - Mechanical testing
ISO TC 150/SC 4/WG 3 - Wear
ISO TC 150/WG 16 - Antimicrobial properties of implants
ISO TC 150/WG 7 - Fundamental standards
IS 10121 (Part 1) : 1982 Reviewed In : 2021 |
Specification for metal bone screws – Mechanical requirements and methods of test Part 1 screws with asymmetrical thread, variable fitting (Spherical), Stainless Steel
|
February, 2021
|
-
|
Indigenous
|
|
IS 10121 (Part 2) : 1982 Reviewed In : 2021 |
Specification for metal bone screws - Mechanical requirements and methods of test Part 2 screws with asymmetrical thread, constant fitting (Spherical), stainless steel
|
February, 2021
|
-
|
Indigenous
|
|
IS 10128 : 2023 |
Knowles Pin (First Revision)
|
-
|
Indigenous
|
||
IS 10155 : 1982 Reviewed In : 2022 |
Specification for blade plate, femoral, lower
|
March, 2022
|
-
|
Indigenous
|
|
IS 10155 : 2024 |
Lower Femoral Blade Plate - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 10235 (Part 1) : 1982 Reviewed In : 2021 |
Glossary of terms Part 1 general medical terms for surgical implants
|
February, 2021
|
-
|
Indigenous
|
|
IS 10235 (Part 2) : 1982 Reviewed In : 2021 |
Glossary of terms in orthopaedics Part 2 mechanics and materials for implants
|
February, 2021
|
-
|
Indigenous
|
|
IS 10235 (Part 3) : 1982 Reviewed In : 2021 |
Glossary of terms in orthopaedics Part 3 orthopaedic surgery
|
February, 2021
|
-
|
Indigenous
|
|
IS 10326 : 1982 Reviewed In : 2021 |
Spreader, Plaster Cast, Henning's Pattern
|
February, 2021
|
-
|
Indigenous
|
|
IS 10327 : 1982 Reviewed In : 2021 |
Bender, Plaster, Bohler's Pattern
|
February, 2021
|
-
|
Indigenous
|
|
IS 10338 : 1982 Reviewed In : 2021 |
Specification for saw, plaster, hand
|
February, 2021
|
-
|
Indigenous
|
|
IS 10349 : 1982 Reviewed In : 2021 |
Rasp for Hip Prothesis, Thompson's and Moore's Patterns
|
February, 2021
|
-
|
Indigenous
|
|
IS 10727 : 2023 |
Nail, Square, Ulna - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 10728 : 2023 |
Nail, Square, Radius - Specification ( First Revision )
|
-
|
Indigenous
|
||
IS 10729 : 1983 Reviewed In : 2021 |
Specification for nail set, kuntscher
|
February, 2021
|
-
|
Indigenous
|
|
IS 10730 : 1983 Reviewed In : 2021 |
Osteotome, Whitchurch Howell's Pattern
|
February, 2021
|
1
|
Indigenous
|
|
IS 11568 : 1986 Reviewed In : 2022 |
Forceps, Bone Holding, Semb's Pattern
|
March, 2022
|
-
|
Indigenous
|
|
IS 11569 : 2023 |
Specification for Cervical Collar (First Revision)
|
-
|
Indigenous
|
||
IS 11569 : 1986 Reviewed In : 2022 |
Specification for cervical collar
|
January, 2022
|
1
|
Indigenous
|
|
IS 11953 : 1986 Reviewed In : 2022 |
Specification for driver and bender for rush intramedullary pin
|
March, 2022
|
-
|
Indigenous
|
|
IS 12088 : 1987 Reviewed In : 2023 |
Specification for bone plate, dynamic compression
|
February, 2023
|
-
|
Indigenous
|
|
IS 12172 : 1987 Reviewed In : 2023 |
Specification for distraction cervical collar
|
March, 2023
|
-
|
Indigenous
|
|
IS 12304 : 1987 Reviewed In : 2023 |
Specification for Plastic Cervical Collar
|
December, 2023
|
-
|
Indigenous
|
|
IS 12304 : 2024 |
Plastic Cervical Collar — Specification (First Revision)
|
-
|
Indigenous
|
||
IS 12304 : 1987 Reviewed In : 2023 |
Specification for plastic cervical collar
|
February, 2023
|
-
|
Indigenous
|
|
IS H12304 : 1987 Reviewed In : 2023 |
Plastic Cervical Collar(HINDI)
|
December, 2023
|
-
|
||
IS 12375 (Part 1) : 2015 ISO 7206-1 : 2008 Reviewed In : 2020 |
Implants for surgery - Partial and total hip joint prostheses Part 1 classification and designation of dimensions (Second Revision)
|
June, 2020
|
-
|
Identical under dual numbering
|
|
IS 12375 (Part 2) : 2018 ISO 7206-2 : 2011 Reviewed In : 2023 |
Implants for surgery - Partial and total hip joint prostheses Part 2 articulating surfaces made of metallic, ceramic and plastics materials (First Revision)
|
May, 2023
|
-
|
Identical under dual numbering
|
|
IS 12375 (Part 4) : 2016 ISO 7206-4 : 2010 Reviewed In : 2022 |
Implants for surgery - Partial and total hip joint prostheses Part 4 determination of endurance properties and performance of stemmed femoral components (First Revision)
|
March, 2022
|
1
|
Identical under dual numbering
|
|
IS 12375 (Part 6) : 2018 ISO 7206-6 : 2013 Reviewed In : 2023 |
Implants for surgery - Partial and total hip joint prostheses Part 6 endurance properties testing and performance requirements of neck region of stemmed femoral components (First Revision)
|
June, 2023
|
-
|
Identical under dual numbering
|
|
IS 12375 (Part 10) : 2023 ISO 7206-10: 2018 |
Implants for surgery - Partial and total hip-joint prostheses Part 10 Determination of resistance to static load of modular femoral heads
|
-
|
Identical under dual numbering
|
||
IS 12375 (Part 12) : 2024 |
Implants for Surgery - Partial and Total Hip Joint Prostheses Part 12: Deformation Test Method for Acetabular Shells
|
-
|
Modified/Technically Equivalent
|
||
IS 12375 (Part 13) : 2024 |
Implants for Surgery � Partial and Total Hip Joint Prostheses Part 13 Determination of Resistance to Torque of Head Fixation of Stemmed Femoral Components
|
-
|
Modified/Technically Equivalent
|
||
IS 12376 (Part 1) : 2015 ISO 7207-1 : 2007 Reviewed In : 2020 |
Implants for surgery - Components for partial and total knee joint prostheses Part 1 classification, definitions and designation of dimensions (Second Revision)
|
December, 2020
|
-
|
Identical under dual numbering
|
|
IS/ISO 12891-1 : 2015 ISO 12891-1 : 2015 Reviewed In : 2023 |
Retrieval and analysis of surgical implants Part 1 retrieval and handling
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 13175-3 : 2012 ISO 13175-3 : 2012 Reviewed In : 2023 |
Implants for surgery - Calcium phosphates Part 3 hydroxyapatite and beta - Tricalcium phosphate bone substitutes
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 13179-1 : 2014 ISO 13179-1 : 2014 |
Implants for Surgery - Plasma Sprayed Unalloyed Titanium Coatings on Metallic Surgical Implants Part 1 General Requirements
|
-
|
Identical under single numbering
|
||
IS/ISO 13356 : 2015 ISO 13356 : 2015 Reviewed In : 2023 |
Implants for Surgery – Ceramic Materials Based on Yttria-Stabilized Tetragonal Zirconia ( Y-TZP )
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS 13423 : 1992 Reviewed In : 2023 |
Good manufacturing practices for orthopaedic implants - Guide
|
December, 2023
|
-
|
Indigenous
|
|
IS/ISO 13779-3 : 2018 ISO 13779-3 : 2018 Reviewed In : 2023 |
Implants for surgery - Hydroxyapatite Part 3 chemical analysis and characterization of crystallinity and phase purity
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 13779-4 : 2018 ISO 13779-4 : 2018 Reviewed In : 2023 |
Implants for surgery - Hydroxyapatite Part 4 determination of coating adhesion strength
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 13779-6 : 2015 ISO 13779-6 : 2015 Reviewed In : 2023 |
Implants for surgery - Hydroxyapatite Part 6 powders
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 13781 : 2017 ISO 13781 : 2017 Reviewed In : 2023 |
Implants for surgery - homopolymers, copolymers and blends on poly (Lactide) - In vitro degradation testing
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS 14227 : 1995 ISO 8615 Reviewed In : 2021 |
Implants for surgery - Fixation devices for use in the ends of the femur in adults
|
February, 2021
|
-
|
Identical under dual numbering
|
|
IS 14228 : 1996 ISO 8827 Reviewed In : 2021 |
Implants for surgery - Staples with parallel legs for orthopaedic use - General requirements
|
February, 2021
|
-
|
Identical under dual numbering
|
|
IS 14229 : 1995 ISO 9585 Reviewed In : 2021 |
Implants for surgery - Determination of bending strength and stiffness of bone plates
|
February, 2021
|
-
|
Identical under dual numbering
|
|
IS 14239 (Part 1) : 2018 ISO 9714-1 : 2012 Reviewed In : 2023 |
Orthopaedic drilling instruments Part 1 drill bits, taps and countersink cutters (First Revision)
|
June, 2023
|
-
|
Identical under dual numbering
|
|
IS/ISO/TR 14283 : 2018 ISO/TR 14283 : 2018 |
Implants for Surgery - Essential Principles of Safety and Performance
|
-
|
Identical under single numbering
|
||
IS/ISO 15309 : 2013 ISO 15309 : 2013 Reviewed In : 2023 |
Implants for surgery - Differential scanning calorimetry of poly ether ether ketone (PEEK) polymers and compounds for use in implantable medical devices
|
March, 2023
|
-
|
Identical under dual numbering
|
|
IS/ISO 16402 : 2008 ISO 16402 : 2008 Reviewed In : 2023 |
Implants for surgery - Acrylic resin cement - Flexural fatigue testing of acrylic resin cements used in orthopaedics
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 17327-1 : 2018 |
Non-active surgical implants - Implant coating Part 1 General requirements
|
-
|
Identical under single numbering
|
||
IS 18074 (Part 1) : 2023 ISO 5834-1: 2019 |
Implants for surgery - Ultra-high-molecular-weight polyethylene Part 1 Powder form
|
-
|
Identical under dual numbering
|
||
IS 18074 (Part 2) : 2023 ISO 5834-2: 2019 |
Implants for surgery - Ultra-high-molecular-weight polyethylene Part 2 Moulded forms
|
-
|
Identical under dual numbering
|
||
IS 18074 (Part 3) : 2024 |
Implants for Surgery - Ultra-high-molecular-weight Polyethylene Part 3 Accelerated Ageing Methods
|
-
|
Modified/Technically Equivalent
|
||
IS 18074 (Part 4) : 2024 |
Implants for Surgery - Ultra-High-Molecular-Weight Polyethylene Part 4 Oxidation Index Measurement Method
|
-
|
Modified/Technically Equivalent
|
||
IS 18074 (Part 5) : 2024 ISO 5834-5:2019 |
Implants for Surgery - Ultra-high-molecular-weight Polyethylene Part 5: Morphology Assessment Method
|
-
|
Identical under dual numbering
|
||
IS 18075 (Part 1) : 2023 ISO 14243-1:2009 |
Implants for surgery - Wear of total knee-joint prostheses Part 1 Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test
|
-
|
Identical under dual numbering
|
||
IS 18075 (Part 2) : 2023 ISO 14243-2: 2016 |
Implants for surgery - Wear of total knee-joint prostheses Part 2 Methods of measurement
|
-
|
Identical under dual numbering
|
||
IS 18075 (Part 3) : 2023 ISO 14243-3:2014 |
Implants for surgery - Wear of total knee-joint prostheses Part 3 Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test
|
-
|
Identical under dual numbering
|
||
IS 18076 : 2023 ISO 14630: 2012 |
Non-active surgical implants - General requirements
|
-
|
Identical under dual numbering
|
||
IS 18078 : 2023 ISO 5836: 1988 |
Implants for surgery - Metal bone plates - Holes corresponding to screws with asymmetrical thread and spherical under-surface
|
-
|
Identical under dual numbering
|
||
IS 18079 : 2023 ISO 9269: 1988 |
Implants for surgery - Metal bone plates - Holes and slots corresponding to screws with conical under-surface
|
-
|
Identical under dual numbering
|
||
IS 18125 (Part 1) : 2023 ISO 14879-1: 2020 |
Implants for surgery - Total knee-joint prostheses Part 1 Determination of endurance properties of knee tibial trays
|
-
|
Identical under dual numbering
|
||
IS 18261 (Part 3) : 2023 ISO 5832-3: 2021 |
Implants for Surgery - Metallic Materials Part 3 Wrought Titanium 6-Aluminium 4-Vanadium Alloy Second Revision
|
-
|
Identical under dual numbering
|
||
IS 18261 (Part 5) : 2023 ISO 5832-5: 2022 |
Implants for Surgery - Metallic Materials Part 5 Wrought Cobalt-Chromium-Tungsten Nickel (First Revision)
|
-
|
Identical under dual numbering
|
||
IS 18261 (Part 6) : 2023 ISO 5832-6: 2022 |
Implants for Surgery - Metallic Materials Part 6 Wrought Cobalt-Nickel-Chromium-Molybdenum Alloy First Revision
|
-
|
Identical under dual numbering
|
||
IS 18359 : 2023 ISO 13779-2:2018 |
Implants for surgery - Hydroxyapatite Part 2 Thermally sprayed coatings of hydroxyapatite
|
-
|
Identical under dual numbering
|
||
IS 18537 (Part 2) : 2024 ISO 12891-2 : 2020 |
Retrieval and analysis of surgical implants Part 2: Analysis of retrieved surgical implants
|
-
|
Identical under dual numbering
|
||
IS 18555 (Part 12) : 2024 ISO 5832-12:2019 |
Implants for surgery - Metallic materials Part 12 Wrought cobalt-chromium-molybdenum alloy
|
-
|
Identical under dual numbering
|
||
IS 18555 (Part 14) : 2024 ISO 5832-14:2019 |
Implants for surgery - Metallic materials Part 14 Wrought titanium 15-molybdenum 5-zirconium 3-aluminium alloy
|
-
|
Identical under dual numbering
|
||
IS 18592 (Part 2) : 2024 ISO/TR 17327-2:2021 |
Non-active surgical implants - Implant coating Part 2 Reference standards related to coatings
|
-
|
Identical under dual numbering
|
||
IS/ISO 19227 : 2018 ISO 19227 : 2018 |
Implants for Surgery - Cleanliness of Orthopedic Implants - General Requirements
|
-
|
Identical under single numbering
|
||
IS/ISO 21534 : 2007 ISO 21534 : 2007 Reviewed In : 2023 |
Non - Active surgical implants - Joint replacement implants - Particular requirements
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 21535 : 2007 ISO 21535 : 2007 |
Non - Active surgical implants - Joint replacement implants - Specific requirements for hip - Joint replacement implants
|
-
|
Identical under single numbering
|
||
IS/ISO 21536 : 2007 ISO 21536 : 2007 |
Non - Active surgical implants - Joint replacement implants - Specific requirements for knee - Joint replacement implants
|
-
|
Identical under single numbering
|
||
IS 5089 : 1969 Reviewed In : 2023 |
Specification for blade plate, blount type
|
February, 2023
|
-
|
Indigenous
|
|
IS 5347 (Part 1) : 1986 Reviewed In : 2022 |
Requirements for orthopaedic implants Part 1 general requirements (Second Revision)
|
March, 2022
|
-
|
Indigenous
|
|
IS 5347 (Part 17) : 2002 ISO 13782 Reviewed In : 2018 |
Requirements for orthopedic implants Part 17 metallic materials - Unalloyed tantalum for surgical implant applications
|
February, 2018
|
-
|
Identical under dual numbering
|
|
IS 5395 (Part 1) : 1989 ISO 5837/1-1985 Reviewed In : 2021 |
Specification for Surgical Implants - Intramedullary nailing systems for bone surgery Part 1 Intramedullary nails with cloverleaf or v - shaped cross - section (Second Revision)
|
February, 2021
|
1
|
Identical under dual numbering
|
|
IS 5396 : 1969 Reviewed In : 2022 |
Specification for guide pin for kuntscher nail
|
March, 2022
|
-
|
Indigenous
|
|
IS 5397 : 1969 Reviewed In : 2022 |
Specification for reamer, flexible for kuntscher nail (Meddulary canal)
|
March, 2022
|
-
|
Indigenous
|
|
IS 5574 : 1970 Reviewed In : 2022 |
Specification for forceps, wire cutting, compound action, orthopaedic
|
March, 2022
|
-
|
Indigenous
|
|
IS 5580 : 1970 Reviewed In : 2022 |
Specification for chisels, stille pattern, orthopaedic
|
March, 2022
|
-
|
Indigenous
|
|
IS 5580 : 2024 |
Stille Pattern Orthopaedic Chisels � Specification (First Revision)
|
-
|
Indigenous
|
||
IS 5581 : 2024 |
Bohler�s Stirrup � Specification (First Revision)
|
-
|
Indigenous
|
||
IS 5583 : 1970 Reviewed In : 2022 |
Specification for osteotomes, stille pattern, orthopaedic
|
March, 2022
|
2
|
Indigenous
|
|
IS 5583 : 2024 |
Stille Pattern Orthopaedic Osteotomes - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 5585 : 1970 Reviewed In : 2022 |
Specification for mallet, rubber-capped
|
March, 2022
|
-
|
Indigenous
|
|
IS 5589 : 1970 Reviewed In : 2022 |
Specification for saw handle, bone amputation, orthopaedic
|
March, 2022
|
-
|
Indigenous
|
|
IS 5590 : 1970 Reviewed In : 2022 |
Specification for saw blade, bone amputation
|
March, 2022
|
-
|
Indigenous
|
|
IS 5601 : 1970 Reviewed In : 2022 |
Specification for gouges, stille pattern, orthopaedic
|
March, 2022
|
1
|
Indigenous
|
|
IS 5803 : 1970 Reviewed In : 2022 |
Specification for twist drill used in orthopaedic surgery
|
March, 2022
|
-
|
Indigenous
|
|
IS/ISO 5832 : 2014 ISO 5832-4 : 2014 Reviewed In : 2023 |
Implants for Surgery – Metallic Materials Part 4 Cobalt-Chromium-Molybdenum Casting Alloy
|
March, 2023
|
-
|
Identical under dual numbering
|
|
IS/ISO 5832-1 : 2016 ISO 5832-1 : 2016 Reviewed In : 2023 |
Implants for surgery - Metallic materials Part 1 Wrought stainless steel
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 5832-2 : 2018 ISO 5832-2 : 2018 |
Implants for surgery - Metallic materials Part 2 Unalloyed titanium (First Revision)
|
-
|
-
|
Identical under single numbering
|
|
IS/ISO 5832-5 : 2005 ISO 5832-5 : 2005 Reviewed In : 2019 |
Implants for surgery - Metallic materials Part 5 wrought cobalt - Chromium - Tungsten - Nickel alloy
|
July, 2019
|
-
|
Identical under single numbering
|
|
IS/ISO 5832-7 : 2016 ISO 5832-7 : 2016 Reviewed In : 2023 |
Implants for surgery - Metallic materials Part 7 Forgeable and cold-formed Cobalt-Chromium-Nickel-Molybdenum-Iron alloy
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS 18261 (Part 9) : 2024 ISO 5832-9:2019 |
Implants for Surgery � Metallic materials Part 9: Wrought High Nitrogen Stainless Steel First Revision
|
-
|
Identical under dual numbering
|
||
IS/ISO 5832-11 : 2014 ISO 5832-11 : 2014 Reviewed In : 2023 |
Implants for surgery - Metallic materials Part 11 Wrought Titanium 6-Aluminium 7-Niobium alloy
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS/ISO 5838-1 : 2013 ISO 5838-1 : 2013 Reviewed In : 2023 |
Implants for Surgery - Metallic Skeletal Pins and Wires Part 1 General Requirements
|
March, 2023
|
-
|
Identical under single numbering
|
|
IS 5847 : 1970 Reviewed In : 2022 |
Specification for pin chuck for introducing steinman pins
|
March, 2022
|
-
|
Indigenous
|
|
IS 5848 : 1996 ISO 5838-2 Reviewed In : 2022 |
Implants for surgery - Skeletal pins and wires - Steinmann skeletal pins - Dimensions (First Revision)
|
March, 2022
|
-
|
Identical under dual numbering
|
|
IS 6187 : 1971 Reviewed In : 2022 |
Specification for saw, wire (Gigli Pattern)
|
March, 2022
|
-
|
Indigenous
|
|
IS 6233 : 2023 |
Bone Cutting Stille Liston Pattern Forceps - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 6252 : 1971 Reviewed In : 2022 |
Scissors Bandage, Lister's Pattern
|
March, 2022
|
-
|
Indigenous
|
|
IS 6252 : 2024 |
Scissors Bandage Listers Pattern - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 6281 : 2023 |
Bone Awl (First Revision)
|
-
|
Indigenous
|
||
IS 6289 : 2024 |
Orthopaedic Epiphyseal Staple - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 6319 : 2024 |
Bone Clamp - Lowman Type - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 6319 : 1971 Reviewed In : 2022 |
Specification for clamp, bone, Lowman type
|
March, 2022
|
-
|
Indigenous
|
|
IS 6371 : 2023 |
Lane's, Lane-Fagge's and Fergusson's Patterns Bone Holding Forceps - Specification ( First Revision )
|
-
|
Indigenous
|
||
IS/ISO 6474-1 : 2010 ISO 6474-1 : 2010 Reviewed In : 2021 |
Implants for surgery - Ceramic materials Part 1 ceramic materials based on high purity alumina
|
January, 2021
|
-
|
Identical under single numbering
|
|
IS 18530 (Part 2) : 2024 ISO 6474-2:2019 |
Implants for surgery Ceramic materials Part 2: Composite materials based on a high-purity alumina matrix with zirconia reinforcement (First Revision)
|
-
|
Identical under dual numbering
|
||
IS 6484 : 2023 |
Fergusson's Pattern Orthopaedic Gouge Forceps - Specification First Revision
|
-
|
Indigenous
|
||
IS 6485 : 2023 |
Angular Orthopaedic Gouge Forceps - Specification ( First Revision )
|
-
|
Indigenous
|
||
IS 6486 : 2024 |
Lane�s Pattern Orthopaedic Gouge Forceps � Specification (First Revision)
|
-
|
Indigenous
|
||
IS 6501 : 2023 |
Stille Luer's Pattern Orthopaedic Gouge Forceps - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 6801 (Part 1) : 1999 ISO 8319-1 Reviewed In : 2021 |
Orthopaedic instruments - Drive connections Part 1 keys for use with screws with hexagon socket heads (Second Revision)
|
February, 2021
|
-
|
Indigenous
|
|
IS 6801 (Part 2) : 1987 ISO 8319/2-1986 Reviewed In : 2023 |
Specification for drive connections for orthopaedic instruments Part 2 Screw drivers for single slot head screws, screws with cruciate slot and cross-recessed head screws (First Revision)
|
February, 2023
|
-
|
Indigenous
|
|
IS 6975 : 1973 Reviewed In : 2024 |
Specification for reamer, trochanteric, orthopedic
|
July, 2024
|
-
|
Indigenous
|
|
IS 6976 : 1973 Reviewed In : 2023 |
Specification for awl, kuntscher, diamond pointed
|
February, 2023
|
1
|
Indigenous
|
|
IS 6982 : 1973 Reviewed In : 2023 |
Specification for gauge for intramedullary nails
|
February, 2023
|
-
|
Indigenous
|
|
IS 7055 : 1973 Reviewed In : 2023 |
Specification for drivers, kuntscher, nail, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7102 : 1973 Reviewed In : 2023 |
Specification for screw, bone, leinbach, medullary
|
February, 2023
|
-
|
Indigenous
|
|
IS 7105 (Part 1) : 1973 Reviewed In : 2023 |
Specification for extractor for kuntscher nail Part 1 handle type
|
February, 2023
|
1
|
Indigenous
|
|
IS 7105 (Part 2) : 1986 Reviewed In : 2022 |
Specification for extractor for kuntscher nail: Part 2 striker type
|
March, 2022
|
-
|
Indigenous
|
|
IS 7106 : 1973 Reviewed In : 2023 |
Specification for extractor, staple, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7107 : 1973 Reviewed In : 2023 |
Specification for punch, staple, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7108 : 1973 Reviewed In : 2023 |
Specification for hammer for kuntscher nail extractor
|
February, 2023
|
-
|
Indigenous
|
|
IS 7109 : 1973 Reviewed In : 2023 |
Specification for starter, staple, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7111 : 1973 Reviewed In : 2023 |
Specification for inserter, staple, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7398 : 2024 |
Farabeuf Pattern Bone Holding Forceps — Specification (First Revision)
|
-
|
Indigenous
|
||
IS 7398 : 1974 Reviewed In : 2023 |
Specification For Forceps, Bone Holding, Farabeuf's Pattern
|
February, 2023
|
-
|
Indigenous
|
|
IS 7435 : 1974 Reviewed In : 2023 |
Rongeur, Ruskin's Pattern
|
February, 2023
|
-
|
Indigenous
|
|
IS 7442 : 1974 Reviewed In : 2023 |
Forceps, Bone Cutting, Straight and Angular, Liston's Pattern
|
February, 2023
|
-
|
Indigenous
|
|
IS 7629 : 1975 Reviewed In : 2023 |
Specification for bender, plate, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7650 : 1975 Reviewed In : 2023 |
Specification for drill, hand, bone, universal, micro and kirschner
|
February, 2023
|
-
|
Indigenous
|
|
IS 7817 : 1975 Reviewed In : 2023 |
Specification for impactor for hip prosthesis
|
February, 2023
|
-
|
Indigenous
|
|
IS 7818 : 1975 Reviewed In : 2023 |
Specification for broach, moore type, for hip prosthesis
|
February, 2023
|
-
|
Indigenous
|
|
IS 7819 : 1975 Reviewed In : 2023 |
Specification for mallet, nylon headed, orthopaedic
|
February, 2023
|
-
|
Indigenous
|
|
IS 7819 : 2024 |
Nylon-Headed Orthopaedic Mallet — Specification (First Revision)
|
-
|
Indigenous
|
||
IS 7841 : 1975 Reviewed In : 2023 |
Specification for compression plate, muller type
|
February, 2023
|
-
|
Indigenous
|
|
IS 7846 : 1975 Reviewed In : 2023 |
Specification for extractor for Hip Prosthesis
|
February, 2023
|
-
|
Indigenous
|
|
IS 8261 (Part 1) : 1976 Reviewed In : 2023 |
Specification for pins and wires, skeletal, traction Part 1 kirschner wires
|
February, 2023
|
1
|
Indigenous
|
|
IS 8261 (Part 2) : 1976 Reviewed In : 2023 |
Specification for pins and wires, skeletal, traction Part 2 guide wires
|
February, 2023
|
1
|
Indigenous
|
|
IS 8261 (Part 3) : 1976 Reviewed In : 2023 |
Specification for pins and wires, skeletal, traction Part 3 pins and wires, fixation and threaded
|
February, 2023
|
1
|
Indigenous
|
|
IS 8332 : 2024 |
Gigli Saw Handle — Specification (First Revision)
|
-
|
Indigenous
|
||
IS 8332 : 1977 Reviewed In : 2023 |
Specification for handle, saw, Gigli
|
February, 2023
|
-
|
Indigenous
|
|
IS 8608 : 1977 Reviewed In : 2023 |
Specification for countersinks, pilot type, for orthopaedic use
|
February, 2023
|
-
|
Indigenous
|
|
IS 8641 : 2015 ISO 5833 : 2002 Reviewed In : 2020 |
Implants for surgery - Acrylic resin cements (Third Revision)
|
December, 2020
|
-
|
Indigenous
|
|
IS 8755 : 1977 Reviewed In : 2023 |
Method for testing biological compatibility of metals for surgical implants
|
December, 2023
|
-
|
Indigenous
|
|
IS 8922 : 1978 Reviewed In : 2022 |
Specification for depth gauge for orthopaedic use
|
March, 2022
|
-
|
Indigenous
|
|
IS 8926 : 2023 |
Bone Skid, Murphy Lane's Pattern - Specification (First Revision)
|
-
|
Indigenous
|
||
IS 9265 : 2023 |
Clamp, Compression, Muller's Pattern - Specification (First Revision)
|
-
|
Indigenous
|
||
IS/ISO 9583 : 1993 ISO 9583 : 1993 |
lmplants for Surgery - Non-Destructive Testing - Liquid Penetrant Inspection of Metallic Surgical Implants
|
-
|
Identical under single numbering
|
||
IS/ISO 9584 : 2021 ISO 9584 : 1993 |
Implants for Surgery - Non-Destructive Testing - Radiographic Examination of Cast Metallic Surgical Implants
|
-
|
Identical under single numbering
|
||
IS 9829 (Part 1) : 1996 ISO 5835 Reviewed In : 2022 |
Implants for surgery - Metal bone screws Part 1 with hexagonal drive connection, spherical under surface of head, asymmetrical thread - Dimensions (First Revision)
|
March, 2022
|
-
|
Identical under dual numbering
|
|
IS 9829 (Part 2) : 1996 ISO 9268 Reviewed In : 2022 |
Implants for surgery - Metal bone screws Part 2 with conical under - Surface of head - Dimensions (First Revision)
|
March, 2022
|
-
|
Identical under dual numbering
|
MHD 2 (25945)
|
Implants for surgery Requirements for production of forgings |
|
MHD 2 (25948)
|
Implants for Surgery Orthopaedic Joint Prosthesis Part 1 Procedure for Producing Parametric 3D Bone Models from CT Data of the Knee |
|
MHD 2 (25949)
|
Implants for Surgery Wear of Total Ankle-Joint Prostheses Loading and Displacement Parameters for Wear-Testing Machines with Load or Displacement Control and Corresponding Environmental Conditions for Test |
|
MHD 2 (26001)
|
Implants for surgery Test solutions and environmental conditions for static and dynamic corrosion tests on implantable materials and medical devices |
|
MHD 2 (26002)
|
Implants for surgery Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods |
|
MHD 2 (26003)
|
Implants for Surgery Mechanical Testing of Implantable Spinal Devices Fatigue Test Method for Spinal Implant Assemblies Using an Anterior Support |
|
MHD 2 (26813)
Revision of: IS 5601:1970 |
Stille Pattern Orthopaedic Gouges Specification First Revision |
|
MHD 2 (26819)
Revision of: IS 5589:1970 |
Saw Handle Bone Amputation Orthopaedic Specification First Revision |
No Records Found |
MHD 2 (26437) Revision of: IS 7105:1973 |
Extractor for Kuntscher Nail Specification Part 1 Handle Type First Revision |
|
MHD 2 (26442) Revision of: IS 7105:1986 |
Extractor for Kuntscher Nail Specification Part 2 Striker Type First Revision |
|
MHD 2 (26444) Revision of: IS 7106:1973 |
Orthopaedic Staple Extractor Specification First Revision |
|
MHD 2 (26446) Revision of: IS 7108:1973 |
Hammer for Kuntscher Nail Extractor Specification First Revision |
|
MHD 2 (26447) Revision of: IS 7107:1973 |
Orthopaedic Staple Punch Specification First Revision |
|
MHD 2 (26449) Revision of: IS 7109:1973 |
Orthopaedic Staple Starter Specification First Revision |
|
MHD 2 (26450) Revision of: IS 7111:1973 |
Orthopaedic Staple Inserter Specification First Revision |
|
MHD 2 (26808) Revision of: IS 12172:1987 |
Distraction Type Cervical Collar Specification |
|
MHD 2 (26809) Revision of: IS 12088:1987 |
Dynamic Compression Bone Plate Specification |
|
MHD 2 (26810) Revision of: IS 11953:1986 |
Driver and Bender for Rush Intramedullary Pin Specification |
|
MHD 2 (26811) Revision of: IS 11568:1986 |
Semb Pattern Bone Holding Forceps Specification First Revision |
|
MHD 2 (26812) Revision of: IS 5601:1970 |
Stille Pattern Orthopaedic Gouges Specification First Revision |
|
MHD 2 (26816) Revision of: IS 5590:1970 |
Bone Amputation Saw Blade Specification First Revision |
|
MHD 2 (26818) Revision of: IS 5089:1969 |
Blount Type Blade Plate Specification First Revision |
|
MHD 2 (26820) Revision of: IS 5585:1970 |
Rubber-Capped Mallet Specification First Revision |
|
MHD 2 (26821) Revision of: IS 5585:1970 |
Rubber-Capped Mallet Specification First Revision |
MHD 2 (26401)
Revision of: IS 5847:1970 |
Pin Chuck for Introducing Steinman Pins Specification First Revision |
|
MHD 2 (26402)
Revision of: IS 6976:1973 |
Kuntscher Diamond Pointed Awl Specification First Revision |
|
MHD 2 (26417)
Revision of: IS 7055:1973 |
Drivers for Kuntscher Nail Specification First Revision |
MHD 2 (25843)
Revision of: IS/ISO 13179:2014 |
Implants for Surgery Coatings on Metallic Surgical Implants Part 1 Plasma-Sprayed Coatings Derived from Titanium or Titanium 6 Aluminum-4 Vanadium Alloy Powders |
|
MHD 2 (25875)
Revision of: IS/ISO 21536:2007 |
Non-Active Surgical Implants Joint Replacement Implants Specific Requirements for Knee-Joint Replacement Implants First Revision |
|
MHD 2 (25876)
Revision of: IS/ISO 21535:2007 |
Non-active surgical implants Joint replacement implants Specific requirements for hip-joint Replacement implants First Revision |
MHD 2 (25841)
|
Implants for Surgery Components for Partial and Total Knee-joint Prostheses Part 2 Articulating Surfaces made of Metal Ceramic and Plastics Materials | |
MHD 2 (25842)
Revision of: IS/ISO 6474:2010 |
Implants for Surgery Ceramic Materials Part 1 Ceramic Materials Based on High Purity Alumina First Revision | |
MHD 2 (25874)
Revision of: IS 5347:2002 |
Implants for Surgery - Metallic Materials - Unalloyed Tantalum for Surgical Implant Applications First Revision | |
MHD 2 (25893)
|
Implants for Surgery Wear of Total Hip-Joint Prostheses Part 1 Loading and Displacement Parameters for Wear-testing Machines and Corresponding Environmental Conditions for Test | |
MHD 2 (25894)
|
Implants for Surgery Wear of Total Hip-Joint Prostheses Part 2 Methods of Measurement | |
MHD 2 (25895)
|
Implants for Surgery Wear of Total Hip-Joint Prostheses Part 3 Loading and Displacement Parameters for Orbital Bearing Type Wear Testing Machines and Corresponding Environmental Conditions for Test | |
MHD 2 (25896)
|
Implants for Surgery Wear of Total Hip-Joint Prostheses Part 4 Testing Hip Prostheses Under Variations in Component Positioning which Results in Direct Edge Loading | |
MHD 2 (25897)
|
Implants for Surgery Wear of Total Knee Prostheses Part 5 Durability Performance of the Patellofemoral Joint | |
MHD 2 (25918)
|
Non-Active Surgical Implants Mammary Implants Particular Requirements | |
MHD 2 (25919)
|
Instruments for Use in Association with Non-Active Surgical Implants General Requirements | |
MHD 2 (25920)
|
Implants for surgery - Test methods of material for use as a cortical bone model | |
MHD 2 (25942)
|
Implants for surgery - General guidelines and requirements for assessment of absorbable metallic implants | |
MHD 2 (25943)
|
Implants for surgery - Specification and verification of synthetic anatomical bone models for testing | |
MHD 2 (25944)
|
Implants for Surgery Two-Part Addition-Cure Silicone Elastomers | |
MHD 2 (25946)
|
Implants for Surgery - Roentgen Stereo Photogrammetric Analysis for the Assessment of Migration of Orthopaedic Implants | |
MHD 2 (25947)
|
Wear of Implant Materials - Polymer and Metal Wear Particles - Isolation and Characterization |
|
IS 10154 : 1982 Reviewed In : 2011 |
Blade Plate Osteotomy Wainwright-hammond s Pattern |
|
IS 10159 : 1982 Reviewed In : 2011 |
Nail Supracondylar Jewett s Pattern |
|
IS 11034 : 2019 ISO 8828 : 2014 |
Implants for surgery guidance on care and handling of orthopaedic implants Second Revision |
|
IS 11088 : 1984 Reviewed In : 2017 |
Guide for retrieval and analysis of metallic orthopaedic implants |
|
IS 11567 (Part 1) : 1986 Reviewed In : 2022 |
Specification for holes and slots for metal bone plates Part 1 corresponding to screws with asymmetrical thread and spherical under - Surfaces |
|
IS 11567 (Part 3) : 1986 Reviewed In : 2022 |
Specification for holes and slots in metal bone plates Part 3 corresponding to screws with asymmetrical thread and conical under - Surfaces |
|
IS 11567 (Part 4) : 1986 Reviewed In : 2022 |
Specification for holes and slots in metal bone plates Part 4 corresponding to screws with symmetrical thread and conical undersurfaces |
|
IS 12165 : 1987 ISO 5839 Reviewed In : 2013 |
Basic Requirements for Orthopedic Joint Prostheses |
|
IS 12375 (Part 3) : 1993 ISO 7206-3 Reviewed In : 2013 |
Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 3 Determination of endurance properties of stemmed femorel components without application of torsion |
|
IS 12375 (Part 5) : 1998 ISO 7206-5 Reviewed In : 2013 |
Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 5 Determination of Resistance to Static Load of Head and Neck Region of Stemmed Femoral Components |
|
IS 12375 (Part 7) : 1998 ISO 7206-7 Reviewed In : 2013 |
Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 7 Endurance Performance of Stemmed Femoral Components without Application of Torsion |
|
IS 12375 (Part 8) : 1998 ISO 7206-8 Reviewed In : 2013 |
Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 8 Endurance Performance of Stemmed Femoral Components with Application of torsion |
|
IS 12375 (Part 9) : 1998 ISO 7206-9 Reviewed In : 2013 |
Implants for surgery - Partial and total hip joint prostheses Part 9 Determination of resistance to torque of head fixation of stemmed femoral components |
|
IS/ISO 12891-2 : 2014 ISO 12891-2 : 2014 |
Retrieval and analysis of surgical implants Part 2 analysis of retrieved surgical implants |
|
IS 14239 : 1995 ISO 9714-1 Reviewed In : 2016 |
Orthopaedic Drilling Instruments - Drill Bits Taps and Countersink Cutters |
|
IS 14240 : 1995 Reviewed In : 2016 |
Orthopaedic implants - General requirements for marking packaging and labelling |
|
IS 5090 : 1969 Reviewed In : 2008 |
Blade Plate Moore Type |
|
IS 5170 : 1969 Reviewed In : 2008 |
Bone Plate Sherman Type |
|
IS 5171 : 1969 Reviewed In : 2011 |
Bone plate kessel osteotomy |
|
IS 5347 (Part 2) : 1993 ISO 5832-1 Reviewed In : 2018 |
Requirements for orthopaedic Implants Part 2 Wrought stainless steel |
|
IS 5347 (Part 3) : 1996 ISO 5832/2-1993 Reviewed In : 2011 |
Requirements for orthopaedic implants Part 3 Unalloyed titanium |
|
IS 5347 (Part 4) : 1996 ISO 5832/3-1990 Reviewed In : 2011 |
Requirements for orthopaedic implants Part 4 Wrought titanium 6-aluminium 4- vanadium alloy |
|
IS 5347 (Part 5) : 2000 ISO 5832/4-1996 Reviewed In : 2016 |
Requirements for Orthopaedic Implants - Part 5 Cobalt-chromium-molybdenum Casting Alloy |
|
IS 5347 (Part 6) : 1996 ISO 5832/5-1993 Reviewed In : 2011 |
Requirements for orthopaedic implants Part 6 Wrought-cobalt-chromium tungsten-nickel alloy |
|
IS 5347 (Part 7) : 2002 ISO 5832-6 Reviewed In : 2017 |
Requirements for Orthopaedic Implants - Part 7 Wrought Cobalt-Nickel-Chromium-Molybdenum Alloy |
|
IS 5347 (Part 8) : 1997 ISO 5832/7-1994 Reviewed In : 2018 |
Requirements for orthopaedic implants Part 8 Forgeable and cold-formed-cobalt-chromium-nickel-molybdenum-iron alloy |
|
IS 5347 (Part 9) : 1998 ISO 6474-1994 Reviewed In : 2019 |
Requirements for orthopaedic implants Part 9 ceramic materials based on high purity alumina First Revision |
|
IS 5347 (Part 10) : 1987 ISO 5834/1-1985 Reviewed In : 2017 |
Requirements for orthopaedic implants Part 10 ultra - High molecular weight polyethylene powder form |
|
IS 5347 (Part 11) : 1987 ISO 5834/2-1985 Reviewed In : 2017 |
Requirements for orthopaedic implants Part 11 ultra - High molecular weight polyethylene moulded form |
|
IS 5347 (Part 12) : 1993 ISO 5832-8 Reviewed In : 2013 |
Requirements for orthopaedic implants Part 12 Wrought cobalt-nickel-chromium molybdenum tungsten iron alloy |
|
IS 5347 (Part 13) : 1997 ISO 5832-9 Reviewed In : 2013 |
Requirements for orthopaedic implants Part 13 Wrought high nitrogen stainless steel |
|
IS 5347 (Part 14) : 1997 ISO 5832-10 Reviewed In : 2013 |
Requirements for orthopaedic implants Part 14 Wrought titanium 5-aluminium 2 5-iron alloy |
|
IS 5347 (Part 15) : 1997 ISO 5832-11 Reviewed In : 2018 |
Requirements for orthopaedic implants Part 15 Wrought titanium 6-aluminium 7-niobium alloy |
|
IS 5347 (Part 16) : 2002 ISO 13781 Reviewed In : 2018 |
Requirements for Orthopaedic Implants - Part 16 Poly L-Lactide Resins and Fabricated Forms for Surgical Implants - In Vitro Degradation Testing |
|
IS 5347 (Part 18) : 2002 ISO 13356 Reviewed In : 2018 |
Requirements for orthopedic implants Part 18 ceramic materials based on yttria - Stabilized tetragonal zirconia Y - TZP |
|
IS 5392 : 1969 Reviewed In : 2011 |
Bone Plates Eggers Type |
|
IS 5393 : 1969 Reviewed In : 2022 |
Specification for screws bone |
|
IS 5394 : 1969 Reviewed In : 2022 |
Specification for prostheses hip |
|
IS/ISO 5832-3 : 2016 ISO 5832-3 : 2016 Reviewed In : 2021 |
Implants for surgery Metallic materials Part 3 Wrought Titanium 6 -Aluminium 4 -Vanadium alloy First Revision |
|
IS/ISO 5832-6 : 1997 |
Implants for surgery Metallic materials Part 6 Wrought Cobalt-Nickel-Chromium-Molybdenum alloy |
|
IS/ISO 5832-8 : 1997 ISO 5832-8 : 1997 Reviewed In : 2019 |
Implants for surgery - Metallic materials Part 8 wrought cobalt - Nickel - Chromium - Molybdenum - Tungsten - Iron alloy |
|
IS/ISO 5834-1 : 2005 ISO 5834-1 : 2005 Reviewed In : 2021 |
Implants for surgery - Ultra - HighMolecular - Weight polyethylene Part 1 powder form |
|
IS/ISO 5834-2 : 2011 ISO 5834-2 : 2011 Reviewed In : 2021 |
Implants for surgery - Ultra - HighMolecular - Weight polyethylene Part 2 moulded forms |
|
IS 5846 : 1970 Reviewed In : 2011 |
Nails Bone Smith Petersen and Watson Jones Patterns |
|
IS 6785 : 1982 Reviewed In : 2010 |
Plate Bone Wainwright Osteotomy |
|
IS 6787 : 1973 Reviewed In : 2008 |
Plate Bone McLaughlin |
|
IS 6790 : 1973 Reviewed In : 2008 |
Plate Bone Intertrochanteric Thornton Type |
|
IS 7110 : 1984 ISO 5837-2 Reviewed In : 2022 |
Specification for pins rush intramedullary First Revision |
|
IS 7701 : 1975 Reviewed In : 2008 |
Plates Bone Spinal Meurig Williams |
|
IS 8261 (Part 4) : 1998 ISO 5838-1 Reviewed In : 2018 |
Pins and wires skeletal traction Part 4 material and mechanical requirements First Revision |
|
IS 8326 : 1977 Reviewed In : 2008 |
Starter Smith Peterson Nail Orthopedic |
|
IS 8609 : 1977 Reviewed In : 2008 |
Nail Hip Jewett Type for Orthopedic Use |
|
IS 8921 : 1978 Reviewed In : 2011 |
Augar-extractor Judet s Pattern |
|
IS 9829 (Part 3) : 1986 Reviewed In : 1997 |
Metal bone screws Part 3 Screws with symmetrical thread conical under surfaces |
|
IS 9829 (Part 4) : 1986 Reviewed In : 2013 |
Metal bone screws Part 4 Screws with asymmetrical thread conical under surfaces |
IS 10128 : 2023 |
Knowles Pin First Revision |
|
IS 10155 : 2024 |
Lower Femoral Blade Plate - Specification First Revision |
|
IS 10326 : 1982 Reviewed In : 2021 |
Spreader Plaster Cast Henning s Pattern |
|
IS 10327 : 1982 Reviewed In : 2021 |
Bender Plaster Bohler s Pattern |
|
IS 10338 : 1982 Reviewed In : 2021 |
Specification for saw plaster hand |
|
IS 10349 : 1982 Reviewed In : 2021 |
Rasp for Hip Prothesis Thompson s and Moore s Patterns |
|
IS 10727 : 2023 |
Nail Square Ulna - Specification First Revision |
|
IS 10728 : 2023 |
Nail Square Radius - Specification First Revision |
|
IS 10729 : 1983 Reviewed In : 2021 |
Specification for nail set kuntscher |
|
IS 10730 : 1983 Reviewed In : 2021 |
Osteotome Whitchurch Howell s Pattern |
|
IS 11568 : 1986 Reviewed In : 2022 |
Forceps Bone Holding Semb s Pattern |
|
IS 11569 : 2023 |
Specification for Cervical Collar First Revision |
|
IS 11953 : 1986 Reviewed In : 2022 |
Specification for driver and bender for rush intramedullary pin |
|
IS 12088 : 1987 Reviewed In : 2023 |
Specification for bone plate dynamic compression |
|
IS 12172 : 1987 Reviewed In : 2023 |
Specification for distraction cervical collar |
|
IS 12304 : 1987 Reviewed In : 2023 |
Specification for Plastic Cervical Collar |
|
IS 12304 : 2024 |
Plastic Cervical Collar Specification First Revision |
|
IS H12304 : 1987 Reviewed In : 2023 |
Plastic Cervical Collar HINDI |
|
IS 12375 (Part 2) : 2018 ISO 7206-2 : 2011 Reviewed In : 2023 |
Implants for surgery - Partial and total hip joint prostheses Part 2 articulating surfaces made of metallic ceramic and plastics materials First Revision |
|
IS 12375 (Part 6) : 2018 ISO 7206-6 : 2013 Reviewed In : 2023 |
Implants for surgery - Partial and total hip joint prostheses Part 6 endurance properties testing and performance requirements of neck region of stemmed femoral components First Revision |
|
IS/ISO 13175-3 : 2012 ISO 13175-3 : 2012 Reviewed In : 2023 |
Implants for surgery - Calcium phosphates Part 3 hydroxyapatite and beta - Tricalcium phosphate bone substitutes |
|
IS/ISO 13356 : 2015 ISO 13356 : 2015 Reviewed In : 2023 |
Implants for Surgery Ceramic Materials Based on Yttria-Stabilized Tetragonal Zirconia Y-TZP |
|
IS/ISO 13779-6 : 2015 ISO 13779-6 : 2015 Reviewed In : 2023 |
Implants for surgery - Hydroxyapatite Part 6 powders |
|
IS 14227 : 1995 ISO 8615 Reviewed In : 2021 |
Implants for surgery - Fixation devices for use in the ends of the femur in adults |
|
IS 14228 : 1996 ISO 8827 Reviewed In : 2021 |
Implants for surgery - Staples with parallel legs for orthopaedic use - General requirements |
|
IS 14239 (Part 1) : 2018 ISO 9714-1 : 2012 Reviewed In : 2023 |
Orthopaedic drilling instruments Part 1 drill bits taps and countersink cutters First Revision |
|
IS 18074 (Part 1) : 2023 ISO 5834-1: 2019 |
Implants for surgery - Ultra-high-molecular-weight polyethylene Part 1 Powder form |
|
IS 18074 (Part 2) : 2023 ISO 5834-2: 2019 |
Implants for surgery - Ultra-high-molecular-weight polyethylene Part 2 Moulded forms |
|
IS 18076 : 2023 ISO 14630: 2012 |
Non-active surgical implants - General requirements |
|
IS 18078 : 2023 ISO 5836: 1988 |
Implants for surgery - Metal bone plates - Holes corresponding to screws with asymmetrical thread and spherical under-surface |
|
IS 18261 (Part 3) : 2023 ISO 5832-3: 2021 |
Implants for Surgery - Metallic Materials Part 3 Wrought Titanium 6-Aluminium 4-Vanadium Alloy Second Revision |
|
IS 18261 (Part 5) : 2023 ISO 5832-5: 2022 |
Implants for Surgery - Metallic Materials Part 5 Wrought Cobalt-Chromium-Tungsten Nickel First Revision |
|
IS 18261 (Part 6) : 2023 ISO 5832-6: 2022 |
Implants for Surgery - Metallic Materials Part 6 Wrought Cobalt-Nickel-Chromium-Molybdenum Alloy First Revision |
|
IS 18359 : 2023 ISO 13779-2:2018 |
Implants for surgery - Hydroxyapatite Part 2 Thermally sprayed coatings of hydroxyapatite |
|
IS 18555 (Part 12) : 2024 ISO 5832-12:2019 |
Implants for surgery - Metallic materials Part 12 Wrought cobalt-chromium-molybdenum alloy |
|
IS 18555 (Part 14) : 2024 ISO 5832-14:2019 |
Implants for surgery - Metallic materials Part 14 Wrought titanium 15-molybdenum 5-zirconium 3-aluminium alloy |
|
IS/ISO 21534 : 2007 ISO 21534 : 2007 Reviewed In : 2023 |
Non - Active surgical implants - Joint replacement implants - Particular requirements |
|
IS/ISO 21535 : 2007 ISO 21535 : 2007 |
Non - Active surgical implants - Joint replacement implants - Specific requirements for hip - Joint replacement implants |
|
IS/ISO 21536 : 2007 ISO 21536 : 2007 |
Non - Active surgical implants - Joint replacement implants - Specific requirements for knee - Joint replacement implants |
|
IS 5089 : 1969 Reviewed In : 2023 |
Specification for blade plate blount type |
|
IS 5347 (Part 1) : 1986 Reviewed In : 2022 |
Requirements for orthopaedic implants Part 1 general requirements Second Revision |
|
IS 5395 (Part 1) : 1989 ISO 5837/1-1985 Reviewed In : 2021 |
Specification for Surgical Implants - Intramedullary nailing systems for bone surgery Part 1 Intramedullary nails with cloverleaf or v - shaped cross - section Second Revision |
|
IS 5396 : 1969 Reviewed In : 2022 |
Specification for guide pin for kuntscher nail |
|
IS 5397 : 1969 Reviewed In : 2022 |
Specification for reamer flexible for kuntscher nail Meddulary canal |
|
IS 5574 : 1970 Reviewed In : 2022 |
Specification for forceps wire cutting compound action orthopaedic |
|
IS 5580 : 2024 |
Stille Pattern Orthopaedic Chisels Specification First Revision |
|
IS 5581 : 2024 |
Bohler s Stirrup Specification First Revision |
|
IS 5583 : 2024 |
Stille Pattern Orthopaedic Osteotomes - Specification First Revision |
|
IS 5585 : 1970 Reviewed In : 2022 |
Specification for mallet rubber-capped |
|
IS 5589 : 1970 Reviewed In : 2022 |
Specification for saw handle bone amputation orthopaedic |
|
IS 5590 : 1970 Reviewed In : 2022 |
Specification for saw blade bone amputation |
|
IS 5601 : 1970 Reviewed In : 2022 |
Specification for gouges stille pattern orthopaedic |
|
IS 5803 : 1970 Reviewed In : 2022 |
Specification for twist drill used in orthopaedic surgery |
|
IS/ISO 5832-1 : 2016 ISO 5832-1 : 2016 Reviewed In : 2023 |
Implants for surgery - Metallic materials Part 1 Wrought stainless steel |
|
IS/ISO 5832-2 : 2018 ISO 5832-2 : 2018 |
Implants for surgery - Metallic materials Part 2 Unalloyed titanium First Revision |
|
IS/ISO 5832-7 : 2016 ISO 5832-7 : 2016 Reviewed In : 2023 |
Implants for surgery - Metallic materials Part 7 Forgeable and cold-formed Cobalt-Chromium-Nickel-Molybdenum-Iron alloy |
|
IS 18261 (Part 9) : 2024 ISO 5832-9:2019 |
Implants for Surgery Metallic materials Part 9 Wrought High Nitrogen Stainless Steel First Revision |
|
IS/ISO 5832-11 : 2014 ISO 5832-11 : 2014 Reviewed In : 2023 |
Implants for surgery - Metallic materials Part 11 Wrought Titanium 6-Aluminium 7-Niobium alloy |
|
IS/ISO 5838-1 : 2013 ISO 5838-1 : 2013 Reviewed In : 2023 |
Implants for Surgery - Metallic Skeletal Pins and Wires Part 1 General Requirements |
|
IS 5847 : 1970 Reviewed In : 2022 |
Specification for pin chuck for introducing steinman pins |
|
IS 5848 : 1996 ISO 5838-2 Reviewed In : 2022 |
Implants for surgery - Skeletal pins and wires - Steinmann skeletal pins - Dimensions First Revision |
|
IS 6187 : 1971 Reviewed In : 2022 |
Specification for saw wire Gigli Pattern |
|
IS 6233 : 2023 |
Bone Cutting Stille Liston Pattern Forceps - Specification First Revision |
|
IS 6252 : 2024 |
Scissors Bandage Listers Pattern - Specification First Revision |
|
IS 6281 : 2023 |
Bone Awl First Revision |
|
IS 6289 : 2024 |
Orthopaedic Epiphyseal Staple - Specification First Revision |
|
IS 6319 : 2024 |
Bone Clamp - Lowman Type - Specification First Revision |
|
IS 6371 : 2023 |
Lane 39 s Lane-Fagge 39 s and Fergusson 39 s Patterns Bone Holding Forceps - Specification First Revision |
|
IS/ISO 6474-1 : 2010 ISO 6474-1 : 2010 Reviewed In : 2021 |
Implants for surgery - Ceramic materials Part 1 ceramic materials based on high purity alumina |
|
IS 18530 (Part 2) : 2024 ISO 6474-2:2019 |
Implants for surgery Ceramic materials Part 2 Composite materials based on a high-purity alumina matrix with zirconia reinforcement First Revision |
|
IS 6484 : 2023 |
Fergusson 39 s Pattern Orthopaedic Gouge Forceps - Specification First Revision |
|
IS 6485 : 2023 |
Angular Orthopaedic Gouge Forceps - Specification First Revision |
|
IS 6486 : 2024 |
Lane s Pattern Orthopaedic Gouge Forceps Specification First Revision |
|
IS 6501 : 2023 |
Stille Luer 39 s Pattern Orthopaedic Gouge Forceps - Specification First Revision |
|
IS 6801 (Part 1) : 1999 ISO 8319-1 Reviewed In : 2021 |
Orthopaedic instruments - Drive connections Part 1 keys for use with screws with hexagon socket heads Second Revision |
|
IS 6801 (Part 2) : 1987 ISO 8319/2-1986 Reviewed In : 2023 |
Specification for drive connections for orthopaedic instruments Part 2 Screw drivers for single slot head screws screws with cruciate slot and cross-recessed head screws First Revision |
|
IS 6975 : 1973 Reviewed In : 2024 |
Specification for reamer trochanteric orthopedic |
|
IS 6976 : 1973 Reviewed In : 2023 |
Specification for awl kuntscher diamond pointed |
|
IS 6982 : 1973 Reviewed In : 2023 |
Specification for gauge for intramedullary nails |
|
IS 7055 : 1973 Reviewed In : 2023 |
Specification for drivers kuntscher nail orthopaedic |
|
IS 7102 : 1973 Reviewed In : 2023 |
Specification for screw bone leinbach medullary |
|
IS 7105 (Part 1) : 1973 Reviewed In : 2023 |
Specification for extractor for kuntscher nail Part 1 handle type |
|
IS 7105 (Part 2) : 1986 Reviewed In : 2022 |
Specification for extractor for kuntscher nail Part 2 striker type |
|
IS 7106 : 1973 Reviewed In : 2023 |
Specification for extractor staple orthopaedic |
|
IS 7107 : 1973 Reviewed In : 2023 |
Specification for punch staple orthopaedic |
|
IS 7108 : 1973 Reviewed In : 2023 |
Specification for hammer for kuntscher nail extractor |
|
IS 7109 : 1973 Reviewed In : 2023 |
Specification for starter staple orthopaedic |
|
IS 7111 : 1973 Reviewed In : 2023 |
Specification for inserter staple orthopaedic |
|
IS 7398 : 2024 |
Farabeuf Pattern Bone Holding Forceps Specification First Revision |
|
IS 7435 : 1974 Reviewed In : 2023 |
Rongeur Ruskin s Pattern |
|
IS 7442 : 1974 Reviewed In : 2023 |
Forceps Bone Cutting Straight and Angular Liston s Pattern |
|
IS 7629 : 1975 Reviewed In : 2023 |
Specification for bender plate orthopaedic |
|
IS 7650 : 1975 Reviewed In : 2023 |
Specification for drill hand bone universal micro and kirschner |
|
IS 7817 : 1975 Reviewed In : 2023 |
Specification for impactor for hip prosthesis |
|
IS 7818 : 1975 Reviewed In : 2023 |
Specification for broach moore type for hip prosthesis |
|
IS 7819 : 2024 |
Nylon-Headed Orthopaedic Mallet Specification First Revision |
|
IS 7841 : 1975 Reviewed In : 2023 |
Specification for compression plate muller type |
|
IS 7846 : 1975 Reviewed In : 2023 |
Specification for extractor for Hip Prosthesis |
|
IS 8261 (Part 1) : 1976 Reviewed In : 2023 |
Specification for pins and wires skeletal traction Part 1 kirschner wires |
|
IS 8261 (Part 2) : 1976 Reviewed In : 2023 |
Specification for pins and wires skeletal traction Part 2 guide wires |
|
IS 8261 (Part 3) : 1976 Reviewed In : 2023 |
Specification for pins and wires skeletal traction Part 3 pins and wires fixation and threaded |
|
IS 8332 : 2024 |
Gigli Saw Handle Specification First Revision |
|
IS 8608 : 1977 Reviewed In : 2023 |
Specification for countersinks pilot type for orthopaedic use |
|
IS 8641 : 2015 ISO 5833 : 2002 Reviewed In : 2020 |
Implants for surgery - Acrylic resin cements Third Revision |
|
IS 8922 : 1978 Reviewed In : 2022 |
Specification for depth gauge for orthopaedic use |
|
IS 8926 : 2023 |
Bone Skid Murphy Lane 39 s Pattern - Specification First Revision |
|
IS 9265 : 2023 |
Clamp Compression Muller 39 s Pattern - Specification First Revision |
|
IS 9829 (Part 1) : 1996 ISO 5835 Reviewed In : 2022 |
Implants for surgery - Metal bone screws Part 1 with hexagonal drive connection spherical under surface of head asymmetrical thread - Dimensions First Revision |
|
IS 9829 (Part 2) : 1996 ISO 9268 Reviewed In : 2022 |
Implants for surgery - Metal bone screws Part 2 with conical under - Surface of head - Dimensions First Revision |