Document Details |
|
Name of Department/Committee : | CHD 36 |
---|---|
Document Number : | CHD 36 ( 26239) |
Document Title [English] : | Methods of Sampling and Test Physical and Chemical for Water and Wastewater Part 85 Detection of selected congeners of polychlorinated dibenzo-p-dioxins and polychlorinated biphenyls Method using a flow immunosensor technique |
Document Title [Hindi] : | जल एवं अपशिष्ट जल के नमूने लेने तथा परीक्षण (भौतिक एवं रसायन) की पद्धतियाँ भाग 85 पॉलीक्लोराइनेटेड डिबेंजो-पी-डाइऑक्सिन और पॉलीक्लोराइनेटेड बाइफिनाइल के चयनित संबंधी का प्रवाह इम्यूनोसेंसर तकनीक विधि द्वारा पता लगाना |
Document Type : | New |
Language : | English |
Priority : | 2 |
ICS Code : | 13.060.50 |
Date of Project Approval : | 25-07-2024 |
Standards to be Superseded : |
Classification Details |
|
Group : | Chemicals, Plastics and their Products including packaging and Environment |
Sub Group : | Environment management |
Sub Sub Group : | Methods of Sampling and test of water and wastewater |
Aspects : | Methods of tests |
Risk : | None |
Certification : | None |
Short Commom Man's Title : | Detection of selected congeners of polychlorinated dibenzo-p-dioxins and polychlorinated biphenyls — |
ITCHS Code : | |
Ministry : |
|
Sustainable development Goals : |
|
Degree of Equivalence : | Identical under dual numbering |
Identical/Equivalent Standards : | 23256:2023 |
Organization Type: | ISO |
Sl.No. | Synosis Points | |
1 | This standard specifies methods and principles for detection of selected congeners of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated biphenyls (PCBs) in water and wastewater using a flow immunosensor. The flow immunosensor utilizes antibodies specific to 2,3,7,8-tetrachlorodibenzop-dioxin (2,3,7,8-TCDD) and 3,3’,4,4’,5pentachlorobiphenyl (3,3’,4,4’,5-PeCB), which have the highest toxic equivalent factor (TEF) value among the congeners of each of PCDDs and PCBs. The method is applicable to timely monitoring of selected congeners of 2,3,7,8-TCDD and 3,3’,4,4’,5-PeCB in water and wastewater to prioritize those for subsequent confirmatory determination. |
Timeline Details |
|||||||
|
|||||||
|
|||||||
|
|||||||
Stages |
|||||
Sl. No. |
Stage | Date of Occurence | Remarks | Circulated to | Files |
1 | Generation of Document Number | 25-07-2024 | ------- | ||
2 | P-Draft | 01-08-2024 | Covering letter generated | ------- | |
3 | P-Draft | 01-08-2024 | Duration : 21 Days Remarks : The Committee decided to circulate it as P-draft |
CHD 36, | ------- |
4 | Skipped to W-Draft | 26-09-2024 | Stage-Changed | ------- | |
5 | WC Draft | 26-09-2024 | Duration : 60 Days Submitted for HOD approval Remarks : The Water Quality Sectional Committee CHD 36 in its 21st meting held on 18092024 decided to issue i ino wide circulation |
------- | |
6 | WC Draft | 04-10-2024 | WC rejected by HOD Remarks: Please discuss regarding the title and IS no |
------- | |
7 | WC Draft | 18-10-2024 | Duration : 60 Days Submitted for HOD approval Remarks : Correction as suggested have been incorporated |
------- | |
8 | WC Draft | 21-10-2024 | WC approved by HOD |
CHDC | ------- |