Document Details
Name of Department/Committee : ETD 09
Document Number : ETD 09 ( 24969)
Document Title [English] : High Voltage Direct Current (HVDC) Power Transmission - Cables with Extruded Insulation and Their Accessories for Rated Voltages Up to 320 KV for Land Applications - Test Methods and Requirements
Document Title [Hindi] : उच्च वोल्टेज दिष्ट धारा (एचवीडीसी) पावर संचारण - भूमि अनुप्रयोगों के लिए 320 केवी तक रेटेड वोल्टेज के लिए एक्सट्रूडेड इन्सुलेशन वाले केबल और उनके सहायक उपकरण परीक्षण के तरीके और अपेक्षाएँ
Document Type : New
Language : English
Priority : 2
ICS Code : 29.060.20
Date of Project Approval : 30-01-2024
Standards to be Superseded :


Classification Details
Group : Electrical Switchgear and Other Electrical Products/Accessories
Sub Group : Cables, Conductors, Wires and Accessories
Sub Sub Group : Power cables
Aspects : Product Specification
Risk : Medium
Certification : Voluntary Certification
Short Commom Man's Title :
ITCHS Code :
Ministry :
  • Ministry of Power
Sustainable development Goals :
  • INDUSTRY, INNOVATION AND INFRASTRUCTURE
Degree of Equivalence : Identical under dual numbering
Identical/Equivalent Standards : IEC 62895: 2017
Organization Type: IEC

::Cross Referenced Indian Standard::
Sl. No. Is No & Year IS Title
1 IS/IEC 60060 : PART 2: 2010 High - Voltage test techniques: Part 2 measuring systems
2 IS 8130: 2013 Conductors for insulated electric cables and flexible cords - Specification (Second Revision)
3 IS 7098 : Part 2: 2011 Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision)
4 IS 13573 : Part 2: 2011 Cable accessories for extruded power cables - Specification: Part 2 for working voltages from 3.3 kV(Ue) up to and including 33 kV(E) - Test requirements (First Revision)

Sl.No. Synosis Points
1 This International Standard specifies test methods and requirements for HVDC transmission power cable systems, employing cables with extruded insulation and their accessories, for fixed land installations, for rated voltages up to and including 320 kV. Within the scope of this standard “extruded insulation” means insulation manufactured by extrusion of either thermoplastic (e.g. polyethylene) or crosslinked (e.g. crosslinked polyethylene, ethylene propylene rubber, etc.) material. The insulation material may be either unfilled or filled (e.g. with mineral or carbon).

Timeline Details


S.No. P-Draft
Completion Date
WC-Draft
Completion Date
Final-Draft
Completion Date
Project
Completion Date(Gazette)
Entered By Entered On
1 27-02-2024 27-06-2024 27-07-2024 27-11-2024 MOHAMMAD ISRAFIL 27-02-2024
Stages
Sl.
No.
Stage Date of Occurence Remarks Circulated to Files
1 Generation of Document Number 30-01-2024 -------
2 P-Draft Waived 27-02-2024 -------
3 WC Draft 27-02-2024 Duration : 30 Days
Submitted for HOD approval
-------
4 WC Draft 29-02-2024 WC approved by HOD
ETDC  ETD 40, -------
5 Skipped to Finalization 04-07-2024 Stage-Changed -------
6 Finalization 16-05-2024 ------ -------
7 Final Draft 04-07-2024 Submited for HOD approval
-------
8 Final Draft draft accepted by HOD and sent to Publication 04-07-2024 Final Draft approved by HOD -------
9 Final Draft draft accepted by HOD and sent to Publication 04-07-2024 Final Draft approved by HOD -------