Document Details |
|
Name of Department/Committee : | ETD 21 |
---|---|
Document Number : | ETD 21 ( 23999) |
Document Title [English] : | Electric welding equipment Assessment of restrictions related to human Exposure to electromagnetic fields 0 Hz to 300 GHz Part 3: Resistance welding equipment |
Document Title [Hindi] : | वैद्युत वेल्डिंग उपकरण - मानव से संबंधित प्रतिबंधों का आकलन विद्युत चुम्बकीय क्षेत्रों के संपर्क में (0 हर्ट्ज से 300 गीगाहर्ट्ज) - भाग 3: प्रतिरोध वेल्डिंग उपकरण |
Document Type : | New |
Language : | English |
Priority : | 1 |
ICS Code : | 25.160.30 |
Date of Project Approval : | 13-10-2023 |
Standards to be Superseded : |
Classification Details |
|
Group : | Electronic and Telecom equipments, components and devices |
Sub Group : | Environment testing for electronic equipments |
Sub Sub Group : | Environmental Testing Procedure for Electronic and Electrical Items |
Aspects : | Methods of tests |
Risk : | Medium |
Certification : | None |
Short Commom Man's Title : | |
ITCHS Code : | |
Ministry : |
|
Sustainable development Goals : | |
Degree of Equivalence : | Identical under dual numbering |
Identical/Equivalent Standards : | IEC 62822-3:2023 |
Organization Type: | IEC |
::Cross Referenced International Standard(s) & Standard(s) Of National SDO(s) :: |
||||||
Sl. No. | Prefix | Number | Part | Section | Year | |
1 | IEC | 60974 | 1 | - | - | |
2 | IEC | 60974 | 6 | - | - | |
3 | IEC | 62311 | - | - | - | |
4 | IEC | 62226 | 1 | - | - | |
5 | IEC | 62822 | 1 | - | - | |
6 | IEC | 60050 | 851 | - | - | |
7 | IEC | 61786 | 1 | - | - | |
8 | IEC | 61786 | 2 | - | 2014 |
Sl.No. | Synosis Points | |
1 | This part of IEC 62822 applies to equipment for resistance welding and allied processes designed for occupational use by professionals and for use by laymen. More generally, this document covers equipment for which the welding current flows in an electrical circuit whose geometry cannot be changed and regardless of the technology of the current generator (for example LF-AC, MF-DC for spot or seam welding or capacitive discharge used for stud welding). This document specifies procedures for the assessment of human exposure to magnetic fields produced by resistance welding equipment. It covers non-thermal biological effects in the frequency range from 0 Hz to 10 MHz and defines standardized test scenarios. |
Timeline Details |
|||||||
|
|||||||
|
|||||||
|
|||||||
Stages |
|||||
Sl. No. |
Stage | Date of Occurence | Remarks | Circulated to | Files |
1 | Generation of Document Number | 13-10-2023 | ------- | ||
2 | P-Draft Waived | 31-10-2023 | ------- | ||
3 | WC Draft | 31-10-2023 | Duration : 30 Days Submitted for HOD approval |
------- | |
4 | WC Draft | 31-10-2023 | WC approved by HOD |
ETDC LITD 09, | ------- |